IPX5 is the first of the jet ratings, and it is the one where the equipment matters most. A jet test is defined by a nozzle, a flow rate, a distance and a duration, and changing any of them changes the test while the label stays the same.
The four parameters
IPX5 uses a nozzle with a 6.3 mm inside diameter, delivering 12.5 litres per minute with a tolerance of about 5 percent, from a distance of 2.5 to 3 metres, for a duration of at least 3 minutes.
The duration is not fixed in the way people assume: it scales with the surface area of the enclosure being tested. A large cabinet is jetted for longer than a small handset, and a report that quotes three minutes for a cabinet has probably under-tested it.
| Parameter | IPX5 | If changed |
|---|---|---|
| nozzle | 6.3 mm | larger nozzle, lower velocity, different impact |
| flow | 12.5 l/min | less water, less accumulation |
| distance | 2.5 to 3 m | closer means higher impact pressure |
| duration | 1 min per m2, min 3 min | short test misses saturation |
Why the distance is specified
A jet loses velocity with distance. At 2.5 metres the impact pressure on the surface is a fraction of what it is at 0.5 metres, and the standard fixes the range so that different laboratories produce comparable results.
Testing closer is a common shortcut, and it is always more severe. It produces failures that would not occur at the specified distance, which is safer than the opposite error but still not the test the product was qualified by.
What the jet does that splash does not
A jet carries momentum into a gap. Splash wets a surface; a jet drives water past a lip and into a cavity, and the mechanism is closer to pressure than to wetting.
That is why products that pass IPX4 fail IPX5 at the same seams: the seam was never asked to resist a directed flow, only a diffuse one.
The seams that fail
A horizontal seam under a projecting edge. The jet is aimed at the edge, water deflects along the seam and finds the gap where two mouldings meet.
A gasket loaded in compression only. A soft gasket seals against static water and deflects under a jet, opening a path at the point of impact.
A label over a seam. The jet lifts the edge of the label and water travels underneath.
A connector with a sealed body and an unsealed panel joint. The connector passes, the hole it sits in does not.
Duration and the accumulation effect
The duration exists so that water can fill any cavity that will hold it. A short jet test coats the product; a full-duration test fills the recesses and then finds out what happens when they overflow.
On a product with an internal channel, the water arrives at a sensitive location only after the channel is full. A three-minute test on a large cabinet stops before that point.
Post-test inspection
Open the product immediately, before drying, and photograph. Water on a live part is a failure; water in a drainage channel is not.
Check the lowest internal surfaces first. Water collects there, and that is where corrosion will start months later, long after the test report has been filed.
What to record
Nozzle diameter, flow rate, distance, duration and the surface area that determined it, plus the positions jetted and the inspection result.
The surface area is the field most often omitted, and it is the one that makes a three-minute result meaningful or meaningless. A report that states the duration without the area has recorded a number that cannot be checked.