IP68 is a statement about liquid water at a defined pressure and time. It says nothing about water vapour, and vapour is how most sealed enclosures fill up. A product that passes immersion with dry internals can be wet inside after a season in service, and the seal was never the problem.
Three paths for vapour
Water vapour moves through a sealed enclosure by three routes, and all three are invisible to an immersion test:
Through the polymer itself. Every plastic has a moisture transmission rate. It is low, but an enclosure wall of a few millimetres over a large area transmits a measurable quantity over months.
Through the gasket. Elastomers transmit vapour more readily than the housing. A gasket that seals liquid water perfectly still passes vapour, especially when the vapour pressure difference is sustained.
Through the cable. A stranded conductor is a tube. Water vapour travels along the strands, through the jacket's end, into the enclosure. This is the path that surprises people most, because the cable looks like a solid object.
| Path | Visible to IP test | Typical rate |
|---|---|---|
| housing wall | no | slow, area dependent |
| gasket | no | moderate, length dependent |
| stranded cable | no | can be fast |
Why it condenses where it does
Vapour spreads evenly until the temperature drops. Then it condenses on the coldest surface, which is usually not where the leak is. On an outdoor enclosure, the coldest point is often the metal lid, a mounting bracket, or a heat sink on the outside wall.
That is why the water is frequently found far from any seam. The seam let vapour in; the cold spot collected it. Investigating the seam finds nothing, because liquid water never passed through it.
The temperature cycling pump
Day-night cycling makes the process worse than a steady state would suggest. During the day, the enclosure warms and internal vapour pressure rises; vapour is pushed outward. At night, it cools and the pressure falls; outside air is drawn in, carrying fresh vapour.
The net effect over a month is a slow accumulation, and the mechanism is the same one that makes a sealed bottle left in the sun draw moisture. The seal is not leaking. It is breathing.
What actually works
A vent membrane. A membrane equalises pressure without letting liquid water through, which removes the pumping action. It does not stop vapour, but it stops the cyclic exchange that drives accumulation, and it lets the enclosure dry out when it warms.
A desiccant. Absorbs what enters, but has a finite capacity. A desiccant without a vent is a sealed system that saturates; a desiccant with a vent lasts much longer because the membrane limits the influx.
Conformal coating on the electronics. Does not stop water entering, but stops it mattering. For products where the enclosure cannot be made vapour-tight, this is often the most effective measure.
Potting or encapsulation. The definitive answer for small assemblies, at the cost of repairability.
Testing for it
An immersion test does not detect this failure mode. What does:
Damp heat testing. Sustained high humidity at elevated temperature, which drives vapour in and reveals the result.
Thermal cycling in a humid atmosphere. The combination that reproduces the pumping action. A product that survives this and stays dry internally has genuinely addressed the problem.
Internal humidity measurement on instrumented samples, which turns the question from "is there water" into "how much and how fast".
The design question
The question to settle early is whether the product needs to exclude liquid water or also water vapour. Those are different requirements with different solutions and very different costs.
Most products are better served by accepting that vapour will enter and designing the electronics to tolerate it, rather than pursuing a vapour-tight enclosure that will be compromised by a cable or a gasket anyway.