Cable glands are installed by hand on most production lines. The instruction says "hand-tight" or "tighten firmly", and the operator complies. The result is a joint whose torque nobody knows — and on an IP-rated enclosure that torque decides whether water enters.
What the gland does
A cable gland performs three functions at once:
Seals the cable. A compression seal closes around the cable sheath.
Seals the entry. A thread seal or an O-ring closes the path between gland and enclosure.
Provides strain relief. The gland grips the cable so that pulling force is not transmitted to the terminals.
All three depend on compression, and compression depends on torque.
| Torque | Seal | Strain relief |
|---|---|---|
| too low | leaks at the entry | cable slips |
| correct | sealed | holds |
| too high | seal deformed, may split | cable crushed, conductor damaged |
Why hand-tight varies so much
Two operators with the same instruction apply torques differing by a factor of two or more. Grip strength, glove thickness, wrist angle and how the gland sits in the hand all change the result.
On a small gland the variation is less important. On a large gland with a stiff seal, the low end of "hand-tight" is nowhere near sealing.
The seal that fails first
In practice the cable seal fails before the entry seal, because the cable seal has less mechanical advantage and a smaller contact area.
The failure is not a dramatic leak. It is capillary ingress: water travels along the cable sheath, under the seal, and into the enclosure over hours. An IPX4 splash test finds nothing; a period of service does.
Torque values come from somewhere
Gland manufacturers publish torque figures, usually a range. A range is used because the correct value depends on the cable diameter and the seal material.
Two practical points:
Use the middle of the range. The bottom end may not seal; the top end may deform the seal permanently.
Re-check after a thermal cycle. A gland tightened cold loses torque when the enclosure warms and the seal takes a set. A second check at operating temperature recovers most of it.
Tools
A torque wrench with the correct gland socket costs less than one field failure. For small glands, a torque screwdriver with an adjustable clutch is sufficient and faster than a wrench.
Where a torque tool is impractical, a marker line across gland and enclosure lets a later inspection detect loosening — not a torque value, but at least evidence of movement.
What to record
Torque value, tool used, cable diameter, and whether the check was done cold or at temperature. A record that says "glands tightened" records an action, not a condition.