The drip tests are the simplest in IEC 60529 and the ones most often performed from memory. Two numbers separate a correct test from a decorative one: the drip rate in millimetres per minute, and the tilt angle in degrees. Both are easy to approximate and both change the outcome.
The two rates
IPX1 delivers water at 1 mm per minute, measured as rainfall equivalent, for 10 minutes with the sample in its normal operating position. IPX2 delivers 3 mm per minute — three times the volume — for a total of 10 minutes, but split across four tilted positions of 2.5 minutes each.
Three times the water in the same total time is not a small difference. On a sample with a horizontal seam, IPX1 may leave the interior dry while IPX2 produces a visible film inside the enclosure within the first two positions.
| Parameter | IPX1 | IPX2 |
|---|---|---|
| Drip rate | 1 mm/min | 3 mm/min |
| Duration | 10 min continuous | 4 × 2.5 min = 10 min |
| Sample position | Normal operating position | Tilted 15° in four directions |
Where the setup goes wrong
The tilt is measured from the wrong reference. The 15° tilt is applied to the sample relative to its normal operating position, not to the turntable. On a sample with a sloped front face, "15° from vertical" and "15° from the operating position" are different tests, and only one of them is IPX2.
The drip rate is set by nozzle count, not by measurement. A drip box with the right number of nozzles can still deliver the wrong rate if the supply pressure is low or a nozzle is clogged. The rate has to be measured — a graduated cylinder under the box for one minute is enough — and checked before each test series, not once a year.
The four positions are not equal. Each tilt direction gets 2.5 minutes, and the sample is returned to the operating position between positions only if the standard's figure requires it. Splitting the time unevenly, or running all four positions for the full 10 minutes, changes the total water load.
Water temperature. The standard specifies the drip water temperature within a range around the sample temperature, so that condensation inside the enclosure is not mistaken for ingress. Cold water on a warm sample produces internal condensation that looks exactly like a leak.
Reading the result
The pass criterion for IPX1 and IPX2 is that water shall not cause harmful effects, and that no water shall be found in quantities that could interfere with operation or safety. This is a judgement call, and it needs a written definition before the test starts — where inside the enclosure water is acceptable, and where it is not.
The practical approach is to photograph the interior before and after, with the same lighting and the same orientation, and to note the location of any water rather than only its presence. "Some water inside" is not a finding; "water on the terminal block at the lower left, about 0.2 ml" is.
Why these two tests get skipped
IPX1 and IPX2 are often treated as formalities because the products that need them are usually also specified for higher levels, and the higher-level test is assumed to cover the lower one. It does not. A jet test at IPX5 can pass a product that fails IPX2, because the failure mode is different: jets hit a small area at high pressure, drips cover the whole top surface at low pressure for ten minutes.
The two tests answer different questions, and the drip test is the cheaper one to run properly. A drip box, a level, a protractor and a graduated cylinder are enough.