IPX7 is the test everyone thinks they can run: put the product in a tank, weigh it down, wait thirty minutes, take it out. The two numbers are 1 m and 30 min. What the numbers do not say is where the metre is measured from, and why the water temperature has more influence on the result than the depth.
Depth is measured to the lowest point
The condition is immersion in water to a depth of 1 m, measured at the lowest point of the enclosure, for 30 minutes. The distinction matters for anything that is not a cube:
- A tall enclosure standing upright has its lowest point near the tank floor, so the top may be well above 1 m and the top seals are tested at a lower pressure differential than the bottom ones.
- A product mounted on a bracket is tested in its service attitude, with the bracket fitted, because the bracket changes where water can be trapped.
- A product with a breather or a membrane vent experiences a pressure inside the enclosure equal to the head of water at the vent, which is not necessarily the lowest point.
The 1 m is not a pressure specification; it is a depth specification that happens to correspond to about 10 kPa of hydrostatic pressure. That is roughly a tenth of an atmosphere, which is why IPX7 seals are modest compared with IPX8 seals rated at tens of metres.
IPX8 is not a higher IPX7
| IPX7 | IPX8 | |
| Depth and duration | 1 m for 30 minutes, fixed by the standard | Agreed between manufacturer and user, and stated on the product |
| Typical values | 1 m, 30 min | 1.5 m for 30 min, or 3 m for 120 min, or 10 m for 2 h |
| Can a product be both | Yes | Yes, and the conditions must both be stated |
A product marked IPX8 alone has no defined depth unless the manufacturer states it. "IPX8" on a datasheet with no depth and no duration is a claim without a test condition, and it is the single most common IP marking problem in product literature.
The 5 K rule and why it decides the result
IEC 60529 requires the temperature difference between the water and the specimen to be no more than 5 K at the start of the test. The reason is not comfort; it is physics. A specimen warmer than the water cools, the air inside contracts, and the resulting partial vacuum draws water in through seals that would not leak at equilibrium. A specimen colder than the water warms, the air inside expands and bubbles out, and the test is easier than intended.
The practical consequences:
- Soak the specimen in the test room until its surface temperature is within 5 K of the water. For a small plastic enclosure this is 30 to 60 minutes; for a metal-cased product with thermal mass it can be several hours.
- Do not test a product straight from a cold store or from a warm production line.
- Record both temperatures. A test report without them cannot be defended if the result is challenged.
Reading ingress after immersion
The pass criterion is that water shall not enter in a quantity causing harmful effects. Reading it needs a defined procedure, because water moves when the specimen is lifted:
- Dry the outside completely before opening. A wet lid deposits water inside as it comes off.
- Open the specimen in the service attitude, so water runs the way it would in use rather than towards the terminals.
- Look for water in three places: on live parts, in cable entries, and in any cavity that traps water against a seal.
- Weigh before and after, if the product is small enough. A mass change of more than a few tenths of a gram is a quantitative indication that something entered, even if the visual inspection is ambiguous.
The failure that looks like a pass
A product that passes IPX7 in the laboratory can still fail in service, for a reason the test does not reproduce: repeated immersion. Each cycle works a seal slightly, and a lip seal that holds at the first immersion can pass water at the fiftieth. Where the product standard does not require cycling, the manufacturer's own validation should. Ten immersion cycles with a dry interval between them finds more real failures than one 30 minute immersion at double the depth.
The other invisible failure is trapped water. A product with a cavity that fills during immersion and drains slowly will pass the test and corrode in the field. Weighing before and after, then again after 24 hours, shows whether water is being retained.
The ingress protection range includes immersion tanks with temperature control and depth marking; the catalogue indexes the jet and drip apparatus for the other water levels.