The jet tests are the part of IEC 60529 most often performed with borrowed equipment and least often documented. The parameters are few, which is exactly why each one has to be right: a jet test with the wrong bore or the wrong flow is not a conservative test, it is a different test.
The two tests in numbers
| IPX5 | IPX6 | |
| Nozzle bore | 6.3 mm | 12.5 mm |
| Flow rate | 12.5 litres per minute | 100 litres per minute |
| Distance | 2.5 to 3 m | 2.5 to 3 m |
| Duration | At least 3 minutes | At least 3 minutes |
| Enclosure movement | Surface to be sprayed moved or the nozzle swept | Same, at higher energy |
The duration is a minimum. If the enclosure is large, the standard expects the sprayed area to be covered completely; a small enclosure may need less than three minutes of actual spray, but most laboratories keep the minimum for consistency.
Flow is the parameter that drifts
Bore size is easy to check with a pin gauge. Flow is not. A pump rated at 100 litres per minute at zero head will not deliver 100 litres per minute through a 12.5 mm nozzle and a 3 m hose. Measure flow at the nozzle with a calibrated rotameter or by timed collection into a container, and record the reading with the test. A jet at 80 litres per minute looks convincing and does not meet IPX6.
Distance is measured from the nozzle, not the wall
The 2.5 to 3 m distance is from the nozzle outlet to the nearest surface of the enclosure. Two common errors:
- Measuring to the far side of a large cabinet, which puts the near face at 1.5 m and over-tests it while under-testing the far face.
- Letting the hose sag so the actual nozzle position differs from the marked stand position.
What the standard means by "no harmful ingress"
IPX5 and IPX6 are not "waterproof" ratings. The criterion is that water does not enter in a quantity or at a location that interferes with operation or compromises safety. A few drops inside a sealed electronics compartment may be acceptable; a drop on a creepage path is not. The judgement therefore needs the enclosure powered, or at least inspected, in its normal mounting orientation.
Setup checklist
- Confirm nozzle bore with a pin gauge and inspect the orifice for wear or burrs.
- Measure flow at the nozzle and adjust until it is within tolerance.
- Set the stand distance at 2.5 to 3 m and lock it.
- Mount the enclosure in its normal orientation, with cable entries fitted as in service.
- Run for at least three minutes per exposed face, then inspect immediately and again after a defined drain time.
- Record bore, flow, distance, duration, water temperature and the inspection result.
After the test
Water that reaches a seal can take hours to show up as a fault. Inspect immediately for standing water, then repeat the functional check after a defined period, typically one hour, and again after 24 hours for outdoor products. Photograph the interior before drying; the photograph is the evidence that the result is real. The ingress protection test range covers jet nozzles, IPX1 to IPX8 rigs and turntables, and the test probe range covers the access probes used before and after the water test.