The IK code rates an enclosure's ability to survive a mechanical impact, from IK00 (no protection) to IK10 (20 joules). It is tempting to pick the highest number and move on, but the rating is meant to match the hazard, and overspecifying wastes money while underspecifying invites a cracked housing. The number is a level of impact energy, and the right level comes from where the equipment lives.
What the IK numbers mean
Each code maps to a defined impact energy delivered by a swinging hammer or a spring hammer at the specified energy. The scale is not linear: it jumps from 0.2 J at IK01 to 20 J at IK10, roughly doubling in steps. A 2 J impact is enough to dent thin plastic; a 20 J impact can break a glazed door.
| Code | Energy | Typical context |
|---|---|---|
| IK06 | 1 J | Light indoor knocks |
| IK07 | 2 J | General indoor equipment |
| IK08 | 5 J | Public indoor, occasional abuse |
| IK09 | 10 J | Light industrial, vandal-prone |
| IK10 | 20 J | Heavy industrial, outdoor exposed |
Matching energy to hazard
Ask what actually hits the enclosure. A panel in a clean office sees stray kicks and dropped tools, so IK07 or IK08 is usually enough. The same panel in a workshop or corridor sees trolleys and deliberate knocks, where IK09 or IK10 earns its cost. Outdoor and roadside housings face the highest exposure and justify the top of the scale. The rating should follow the environment, not a desire to look rugged.
- Office and lab: IK06 to IK08.
- Public-access indoor: IK08 to IK09.
- Industrial floor and outdoor: IK09 to IK10.
- Do not assume a high IP rating implies a high IK rating; they are separate.
Mounting height matters
The standard applies impacts at points on the enclosure, and the relevant hazard depends on reach. A device at floor level is kicked; one at eye level is struck by objects; one overhead is mostly hit by falling items. When in doubt, rate for the worst practical point of impact, and remember that a rating taken on a flat panel does not automatically cover a thin door or a protruding window.
After the rating
An IK rating is only real if the test was done on the finished enclosure, including its door, window and fixings, not on a coupon of the same plastic. A glazed door that cracks at 5 J does not make a 20 J enclosure. Record the rating with the configuration it was tested on, and keep the test hammer calibrated, because an IK number backed by an uncalibrated hammer is not a number anyone can defend.