				Clause
			 | 
			
				Measurement/testing
			 | 
			
				Testing
  /measuring equipment/material needed
			 | 
		
		
			| 
				3.4
			 | 
			
				Testofmarking
			 | 
			
				Pieceofcloth/Water/Petroleumspirit
			 | 
		
		
			| 
				4.4.4
			 | 
			
				Lampholderpressuretest
			 | 
			
				Testcaps/Pressuredevice/Torquedriver
			 | 
		
		
			| 
				4.4.5
			 | 
			
				Voltageacrosslampholders
			 | 
			
				Highvoltageprobe/Oscilloscope
			 | 
		
		
			| 
				4.11.6
			 | 
			
				Electro-mechanical contactsystem
			 | 
			
				Lowvoltagevariablecurrentpowersupply,voltmeter,high
  voltagetransformer
			 | 
		
		
			| 
				4.12.1/4.12.5
			 | 
			
				Screwsandconnections(mechanical)and glandstesting
			 | 
			
				Testscrewdriverorspanner/Testrods
			 | 
		
		
			| 
				4.13.1/4.13.4
			 | 
			
			 | 
			
				Spring-operatedimpacttestapparatus/Apparatusforball
  impact   tests/Conditioningcabinet(e.g.freezer)/Angle 
			 | 
		
		
			| 
				4.13.6/4.21.4
			 | 
			
				Mechanical
  strengthtests
			 | 
			
				measuringdevice/Weightingdevice/Tumblingbarrel
  test equipment
			 | 
		
		
			| 
				4.14.1/4.14.2
			 | 
			
				Adjustingdevicestesting
			 | 
			
				Glasstestshelves/
   Weightingdevice/Testapparatusfor adjustabledevices
			 | 
		
		
			| 
				4.14.3
			 | 
		
		
			| 
				4.9.2/4.18.1
			 | 
			
				Insulatingliningsandsleevestests/ Resistancetocorrosion
			 | 
			
				Heatingcabinet,humiditycabinet,megaohmeter,highvoltage
  transformer
			 | 
		
		
			| 
				4.18.2/ AnnexF
			 | 
			
				Stresscorrosion
			 | 
			
				Closeableglassvessel
  /testsolution/Heatingcabinet/Facilities towashsamplesaftertest
			 | 
		
		
			| 
				4.2
			 | 
			
				Roughserviceluminaires
			 | 
			
				Vibrationtestequipment
			 | 
		
		
			| 
				4.22
			 | 
			
				Attachmenttolamps
			 | 
			
				Weighingdevice
			 | 
		
		
			| 
				4.24/AnnexP
			 | 
			
				ProtectivemeasuresagainstUV radiation
			 | 
			
				UV radiationtestinstruments
			 | 
		
		
			| 
				4.26
			 | 
			
				Shortcircuitprotectiontest
			 | 
			
				Testchain/  Weightingdevice
			 | 
		
		
			| 
				5.2.10.1
			 | 
			
				Pull andtorquetestsoncordanchorage
			 | 
			
				Cordanchoragetestsapparatus(pull andtorque)
			 | 
		
		
			| 
				5.3
			 | 
			
				Internal wiringdimensions
			 | 
			
				Micrometer/Equipmentforinsulationthickness
			 | 
		
		
			| 
				7.2.3
			 | 
			
				Earthcontinuitytest
			 | 
			
				Earthingtestequipment
			 | 
		
		
			| 
				8.2.5
			 | 
			
				Protectionagainstelectricshocktests/ Capacitordischarge
			 | 
			
				Standardtestfinger(IEC 60529)/Unjointedtestfinger
			 | 
		
		
			| 
				8.2.7
			 | 
			
				Voltmeter/oscilloscope
			 | 
		
		
			| 
				9.2.0
			 | 
			
				Solidobjectproofluminairetesting
			 | 
			
				IP 3X (2,5mm)/IP 4X (1mm)probes
			 | 
		
		
			| 
				9.2.1/9.2.2
			 | 
			
				Dustproofluminairetests
			 | 
			
				Apparatusforprovingprotectionagainstdust
			 | 
		
		
			| 
				9.2.3,4,5,6,7,
			 | 
			
				Waterproofluminairestesting
			 | 
			
				Apparatusforprotectionagainstwatertests
			 | 
		
		
			| 
				8,9
			 | 
		
		
			| 
				9.3.1
			 | 
			
				Humiditytests
			 | 
			
				Humiditycabinet
			 | 
		
		
			| 
				10.2.1
			 | 
			
				Insulationresistancetests
			 | 
			
				Megaohmmeter
			 | 
		
		
			| 
				10.2.2
			 | 
			
				Electricstrengthtests
			 | 
			
				Highvoltagetransformer
			 | 
		
		
			| 
				10.3.1
			 | 
			
				Leakagecurrenttesting
			 | 
			
				Leakagecurrenttester
			 | 
		
		
			| 
				11.2.1
			 | 
			
				Creepagedistancesandclearances measurements
			 | 
			
				Digital calliper(orequivalent)
			 | 
		
		
			| 
				12.3.1
			 | 
			
				Endurancetests
			 | 
			
				Thermal cabinet(35°C)/Endurancetestequipment/Multimeter
			 | 
		
		
			| 
				/Wattmeter
			 | 
		
		
			| 
				12.4.1
			 | 
			
				Thermal tests
			 | 
			
				Draught-proofenclosure(25°C)/Thermometer/Thermocouples
			 | 
		
		
			| 
				/Voltagestabilizer/Multimeter/Wattmeter
			 | 
		
		
			| 
				12.5.1e)
			 | 
			
				Abnormal
  operationtesting
			 | 
			
				Testcircuitformetal
  halideluminaires
			 | 
		
		
			| 
				AnnexC Fig.C3
			 | 
		
		
			| 
				12.7.2
			 | 
			
				Testforluminaireswithtemperaturesensing
			 | 
			
				Relevantequipmentofclauses15.3and20.5,EquipmentListof
			 | 
		
		
			| 
				controlsinternal/external totheballastor
  transformer
			 | 
			
				IEC
  61558-1,Edition2-2005
			 | 
		
		
			| 
				13.2.1
			 | 
			
				Resistancetoheattest
			 | 
			
				Heatingcabinet/Ball pressuretestapparatus(seealsoCTL
  D.S.N.391.mod)
			 | 
		
		
			| 
				13.3.1
			 | 
			
				Resistancetoflametest
			 | 
			
				Needleflametestapparatus
			 | 
		
		
			| 
				13.3.2
			 | 
			
				Resistancetoignitiontesting
			 | 
			
				Glow-wiretestapparatus
			 | 
		
		
			| 
				13.4.1
			 | 
			
				Resistancetotrackingtest
			 | 
			
				Prooftrackingtestdevice
			 | 
		
		
			| 
				14
			 | 
			
				Screwterminals
			 | 
			
				Torquedrivers,testcables,pull device,micrometer,timer
			 | 
		
		
			| 
				15
			 | 
			
				Screwlessterminals
			 | 
			
				Pull
  device,variablecurrentsource,voltmeter,heatingcabinet,timer,testcables
			 |